VEGA VEGAPULS 56V User Manual

Page 20

Advertising
background image

20

VEGAPULS 56V

PN 16

PN 25

PN 40

PN 64

bar

40

25

16

-40

0

50

100

150

200

250

300

350

˚C

64

Flange DIN DN 50
Material: 1.4571
Groove and tongue acc.
to DIN 2512 form F, N

bar

40

25

16

-40

0

50

100

150

200

250

300

350

˚C

PN 16

PN 25

PN 40

Flange DIN DN 50
Material: 1.4571
Seal surface acc. to
DIN 2526 form B, C, D, E

Measuring characteristics

Frequency

5,8 GHz (USA 6,3 GHz)

Intervals

0,6 s

Min. span between full and
empty adjustment

10 mm (recommended 50 mm)

Beam angle (at –3 dB)
- with DN 80

38

°

(only for standpipe measurement)

- with DN 100

30

°

(only for standpipe measurement)

- with DN 150

20

°

- with DN 200

16

°

- with DN 250

14

°

Ambient conditions

Ambient temperature on the housing

-20

°

C … +60

°

C

Flange temperature (process temperat.) -40

°

C … +350

°

C (pressure dependent), see

following diagrams

Vessel isolation

with process temperatures of more than 200

°

C

the rear of the flange must be covered with a
heat isolation, see chapter "4 Mounting and
installation“.

Storage and transport temperature

-40

°

C … +80

°

C

Protection

IP 66/IP 67

Protection class
- two-wire sensor

II

- four-wire sensor

I

Overvoltage category

III

Vessel pressure

max. 64 bar (temperature dependent), see
following diagrams

Burst pressure
- at 20

°

C

> 400 bar

- at 350

°

C

> 250 bar

Technical data