VEGA VEGAPULS 56V User Manual
Page 23
VEGAPULS 56V
23
Technical data
Flange DIN DN 250
Material: 1.4571
Groove and tongue acc.
to DIN 2512 form F, N
PN 16
PN 25
PN 40
PN 64
bar
40
25
16
64
-40
0
50
100
150
200
250
300
350
˚C
PN 16
PN 25
PN 40
bar
40
25
16
-40
0
50
100
150
200
250
300
350
˚C
Flange DIN DN 250
Material: 1.4571
Seal surface acc. to
DIN 2526 form B, C, D, E
Flanges according to ANSI (ASA) B16.5 seal surface RF, material 1.4571 in sizes 2“ to 10“
can be used over the complete temperature range of -40
°
C␣ …␣ 350
°
C with the appropriate
nominal pressures of 150␣ lbs, 300␣ lbs, 600␣ lbs and 900␣ lbs.
Further flanges and appropriate process data on request.
Connection lines
Two-wire sensors
supply and signal via one two-wire line;
max. line resistance 15␣
Ω
per wire or 1000 m cable length
Cross-section area of conductor
generally 2,5 mm
2
Earth connection
max. 4 mm
2
Cable entry
- Ex ia-terminal box (adjustment module) 2 x M20 x 1,5 (cable diameter 5 … 9 mm)
- Ex d-connection housing
2 x
1
/
2
“ NPT EEx d (cable diameter of the
connection cable 3,1␣ …␣ 8,7␣ mm or
0,12 … 0,34 inch)