23

Technical data

Flange DIN DN 250
Material: 1.4571
Groove and tongue acc.
to DIN 2512 form F, N

PN 16

PN 25

PN 40

PN 64

bar

40

25

16

64

-40

0

50

100

150

200

250

300

350

˚C

PN 16

PN 25

PN 40

bar

40

25

16

-40

0

50

100

150

200

250

300

350

˚C

Flange DIN DN 250
Material: 1.4571
Seal surface acc. to
DIN 2526 form B, C, D, E

Flanges according to ANSI (ASA) B16.5 seal surface RF, material 1.4571 in sizes 2“ to 10“
can be used over the complete temperature range of -40

°

C␣ …␣ 350

°

C with the appropriate

nominal pressures of 150␣ lbs, 300␣ lbs, 600␣ lbs and 900␣ lbs.

Further flanges and appropriate process data on request.

Connection lines

Two-wire sensors

supply and signal via one two-wire line;
max. line resistance 15␣

per wire or 1000 m cable length

Cross-section area of conductor

generally 2,5 mm

2

Earth connection

max. 4 mm

2

Cable entry
- Ex ia-terminal box (adjustment module) 2 x M20 x 1,5 (cable diameter 5 … 9 mm)
- Ex d-connection housing

2 x

1

/

2

“ NPT EEx d (cable diameter of the

connection cable 3,1␣ …␣ 8,7␣ mm or
0,12 … 0,34 inch)