Read/write data fifo, Read data fifo, Write data fifo – Rainbow Electronics AT89C5122 User Manual

Page 102

Advertising
background image

102

AT8xC5122/23

4202E–SCR–06/06

Read/Write Data FIFO

Read Data FIFO

The read access for each OUT endpoint is performed using the UEPDATX register.

After a new valid packet has been received on an Endpoint, the data are stored into the
FIFO and the byte counter of the endpoint is updated (UBYCTX register). The firmware
has to store the endpoint byte counter before any access to the endpoint FIFO. The byte
counter is not updated when reading the FIFO.

To read data from an endpoint, select the correct endpoint number in UEPNUM and
read the UEPDATX register. This action automatically decreases the corresponding
address vector, and the next data is then available in the UEPDATX register.

Write Data FIFO

The write access for each IN endpoint is performed using the UEPDATX register.

To write a byte into an IN endpoint FIFO, select the correct endpoint number in UEP-
NUM and write into the UEPDATX register. The corresponding address vector is
automatically increased, and another write can be carried out.

Warning 1: The byte counter is not updated.
Warning 2: Do not write more bytes than supported by the corresponding endpoint.

Figure 54. Endpoint FIFO Configuration

Endpoint 0 - bank 0

Endpoint 1 - bank 0

Endpoint 2 - bank 0

Endpoint 3 - bank 0

Endpoint 4 - bank 0

Endpoint 5 - bank 0

Endpoint 6 - bank 0

Endpoint 6 - bank 1

8 Bytes

32 Bytes

8 Bytes

8 Bytes

64 Bytes

2 x 64 Bytes

B

a

se

A

d

d

res

ses

00H

20H

28H

30H

38H

78H

B8H

F8H

138H

64 Bytes