Procedure for cvcc = 5volts – Rainbow Electronics AT89C5122 User Manual

Page 92

Advertising
background image

92

AT8xC5122/23

4202E–SCR–06/06

Procedure for CVcc = 5volts

The DC/DC pump mode must be selected (MODE = 0 in DCCKPS register). The
detailed procedure is described in flow chart of Figure 48.

Figure 48. Card Vcc = 5V Initialization Procedure

While VCC remains higher than 4.0V and startup current lower than 30 mA (depending
on the load type), the DC/DC converter should be ready without having to increment
BOOST[1:0] bits beyond [0:0] level. If VCC > 4.0V and startup current > 30 mA, it will be
necessary to increment the BOOST[1:0] bits until the DC/DC converter is ready.

Incrementation of BOOST[1:0] bits increases at the same time the current overflow level
in the same proportion as the startup current. So once the DC/DC converter is ready it is

SCCON CardVcc=1

VCARDOK=1

Set Timeout to 3 ms

Timeout

Expired

Increment

BOOST [1:0]

BOOST[1:0]

= max = 3?

DC/DC Initialization

Failure

DC/DC Initialization

Successful

Decrement

BOOST[1:0]
to adjust the

current overflow

Mode Pump

DCCKPS[7]=0

BOOST[1:0]=[0:0]

SCICR.7=Reset=0

SCICR.7=Reset=1

VCARD[1:0] = 11

BOOST[1:0]

= [0:0]