AT8xC5122/23

4202E–SCR–06/06

Figure 109. Power-down Exit Waveform

Exit from power-down by reset redefines all the SFRs, exit from power-down by external
interrupt does no affect the SFRs.

Exit from power-down by either reset or external interrupt does not affect the internal
RAM content.

Note:

If idle mode is activated with power-down mode (IDL and PD bits set), the exit sequence
is unchanged, when execution is vectored to interrupt, PD and IDL bits are cleared and
idle mode is not entered.

Table shows the state of ports during idle and power-down modes.

Note:

1. Port 0 can force a 0 level. A "one" will leave port floating.

Reduced EMI Mode

The ALE signal is used to demultiplex address and data buses on port 0 when used with
external program or data memory. Nevertheless, during internal code execution, ALE
signal is still generated. In order to reduce EMI, ALE signal can be disabled by setting
AO bit.

The AO bit is located in AUXR register at bit location 0. As soon as AO is set, ALE is no
longer output but remains active during MOVX and MOVC instructions and external
fetches. During ALE disabling, ALE pin is weakly pulled high.

INT1

INT0

XTAL1

Power-down phase

Oscillator restart phase

Active phase

Active phase

Table State of Ports

Mode

Program Memory

ALE

PSEN

P0

P1

P2

P3

P4

P5

Idle

Internal

1

1

Port Data

(1)

Port Data

Port Data

Port Data

Port Data

Port Data

Idle

External

1

1

Floating

Port Data

Address

Port Data

Port Data

Port Data

Power-down

Internal

0

0

Port Dat*

Port Data

Port Data

Port Data

Port Data

Port Data

Power-down

External

0

0

Floating

Port Data

Port Data

Port Data

Port Data

Port Data