AT8xC5122/23
4202E–SCR–06/06
Figure 60. Example of REMOTE WAKEUP Management
USB Controller Init
Detection of a SUSPEND state
SPINT
Set RMWUPE
Suspend management
Enable Clocks
upstream RESUME sent
UPRSM
Clear SPINT
Set SDMWUP
Clear SDRMWUP
SET_FEATURE: DEVICE_REMOTE_WAKEUP
Need USB Resume
UPRSM = 1