Monitoring procedure – Rainbow Electronics AT89C5122 User Manual

Page 93

Advertising
background image

93

AT8xC5122/23

4202E–SCR–06/06

advised to decrement the BOOST[1:0] bits to restore the overflow current to its normal
or desired value.

Monitoring Procedure

Once the DC/DC has been successfuly initialized, it is necessary to monitor the DC/DC
converter by means of bits VCARDOK and ICARDOVF in the SCISR register.

Table 60. DC/DC converter status

VCARDOK

ICARDOVF

DC/DC Status

0

0

- Not Started or switched off by application.

The current overflow sensor is disabled during the DC/DC converter startup. Then if a current
overflow condition is applied during the DC/DC converter startup, the DC/DC converter is unable
to start and both bits VCARDOK and ICARDOVF remains at 0.

DC/DC converter correctly started then the output voltage is out of ISO/IEC 7816-3
specifications. In this case the firmware must take appropriate actions like deactivating the
DC/DC converter in compliance with ISO/IEC 7816.

0

1

Started and automatically switched off by a current overflow condition

1

0

Operating properly according to ISO/IEC 7816-3 and EMV recommendations

1

1

Not applicable