2 digital input setting – SENA Rhio10 User Manual

Page 34

Advertising
background image

34

-

After output control is completed, Rhio10 returns the states of all ports to the host

computer.

4.2 Digital Input Setting

Rhio10 has 12 digital input ports. You can enable/disable each of these digital input ports with

Rhio Manager or by issuing the commands specified in "Ch. 5 I/O Port Related Protocols".

When setting the digital input with Rhio Manager, place your mouse cursor over the Digital Input

LED on the I/O Port Control screen and right-click it to display the Setting window.

4.2.1 Setting Enable/Disable

Figure 4-3 Setting digital input

Digital input setting has two options: Enable and Disable. After selecting either of the options,

press the [Setting] button to apply it in the system. A port cannot be set while it is operating in

Run mode. Therefore, Rhio Manager sends a command that switches its mode to Setting mode

first and then issues the set command when its operation is stopped.

When set to Enable, Rhio Manger receives the ON/OFF state from the device connected to a

digital input port and then displays it. When set to Disable, it displays Disable regardless of the

ON/OFF state of the device connected to the input port.