To configure the RHIO10 to work as a TCP server/client mode, use ‘set’ command as follows:

set host tcpsc listening_port dest_ip dest_port cyclic_connection_interval inactivity_timeout

where,

listening_port = listening TCP port

dest_ip = destination IP address

dest_port = destination TCP port

cyclic_connection_interval = cyclic connection interval in minutes

inactivity_timeout = inactivity timeout in seconds.

The parameter of the TCP Server/Client mode is same as the ones of the TCP server mode and

client mode

> set host tcpsc 6001 192.168.1.100 7001 10 300
OK
>

B.3.3 System Administration

Users can configure administrator username, password and device name using set command

as follows:

set admin username password devicename

username: login username

password: login password

devicename: device name

> set admin adminuser adminpassword Rhio10_test1
OK
>