“00000”

“50000”

OFF after 5,000 sec delay

“00001”

“00001”

Repeat 100 ms ON and 100 ms OFF.

“00020”

“00020”

Repeat 2 sec ON and 2 sec OFF.

“50000”

“50000”

Repeat 5,000 sec ON and 5,000 sec

OFF.

“00010”

“00030”

Repeat 1 sec ON and 3 sec OFF.

“00300”

“00150”

Repeat 30 sec ON and 15 sec OFF.

5.3.5.2 Response for Set Output Port command

Response

Data

Remark

Byte

Size

2

1

2

1

N

“06”

( 0x30,

0x36 )

Return

setting.

Setting

Flag

Port

No.

“01”

-

“10”

0x30: Clear run condition

0x31: Set run condition

0x32: Clear Delay/Pulse

0x33: Set Delay/Pulse

0x39: Clear all settings

Setting

Data

Return the setting

of an output port.

-

Setting Flag

0x30: Set OK

0x39: Set NG

0x31: Not in Setting mode (when in Run mode)

0x32: Unspecified (If the user attempts to clear in unspecified state, it will return 0x32.)

(When it is in unspecified state, the setting data is 0x30 in 1 byte.)

-

When setting is cleared, the setting data is 0x30 in 1 byte.

5.3.5.3 Check Output Port Setting Command

Command

Data

Remark

Byte Size

2

2

1

“07”

( 0x30, 0x37 )

Check setting.

Port No.

“01” - “10”

0x31:

Check

the

run

condition setting.

0x33:

Check

the

Delay/Pulse setting

Check the attribute

of each output port.