SENA Promi-MSP User Guide User Manual

Page 53

Advertising
background image

53

Copyright © 2006 Sena Technologies, Inc. All rights reserved.

DISC <idx>

:

Promi-MSP may DISCONNECT forcibly by DISC command, giving INDEX

value in LIST command.

Ex.:

LIST

0|0|5000|00:0B:53:00:00:8A|SDv3b-00008A|0|0

+OK

DISC 0

+OK

LIST

+OK

LINKTO <timeout>

:

When a Bluetooth device is disconnected by turning off its power, Promi-

MSP has default time out of 20 seconds in finally closing the connection.

You may assign the time out from 1 second up to 30 seconds.

Ex.:

LINKTO 20

+OK

MAXDT <number of max. connections>

:

To assign maximum Bluetooth devices concurrently connectable to

Promi-MSP

™ .

Default value is 7.

Each additional USB extension

module adds up to 7 more Promi-MSP

™ connectable Bluetooth devices.

Ex.:

MAXDT 7

+OK

PINQ <on|off> <interval> <length> <IAC>

:

If PINQ (periodic inquiry) is ON, Promi-MSP will inquire nearby Bluetooth

devices periodically, by each <interval> seconds, for <length> time.

Inquired result can be checked by NGBRH command.

Note:

Promi-MSP normally acts as an acceptor. Do not use CONN command in

operating sequence as Promi-MSP will freeze during CONN operation.

If using with Promi-SD, please configure Promi-SD as Mode 1 and make

it initiate connection to Promi-MSP.