Multi serial communication via rs232 interface – SENA Promi-MSP User Guide User Manual

Page 59

Advertising
background image

59

Copyright © 2006 Sena Technologies, Inc. All rights reserved.

AT+BTUNREG

Remove registered Mode 1 device.

AT+BTUNREG,000b53123456

AT+BTLIST?

Show registered Mode 1 devices.

AT+BTLIST?

000B53123456

000B53112233

OK

Multi Serial Communication via RS232 interface

Promi-MSP can communicate with Promi-SDs up to 14 devices via RS232 interface, while

Promi-SD can be only used as 1:1 cable replacement.

Even though Promi-MSP supports multiple serial connections, because RS232 interface is

inherently 1:1 communication protocol, user should communicate with serial devices

sequentially. Data coming from non-selected Promi-SD is buffered on Promi-MSP and retrieved

when corresponding Promi-SD is selected by ATO command.

If link is lost with currently selected device, one of connected devices will be selected arbitrarily.

Accepting new incoming connection

When incoming connection is established in command mode, Promi-MSP responds with

CONNECT message and enters to online mode.

When incoming connection is established in online mode, CONNECT message is not printed

and selected device with which Promi-MSP communicates won’t be changed.

You can check out all connected devices by AT+BTCONN? command in command mode.

Disconnecting device

You can disconnect Bluetooth device by ATH command in command mode. With specified

device address, any connected device, selected or not, can be disconnected.

Advertising