CDT900 Series Touchscreen Programmable Thermostata

1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED
2. FACTORY INSTALLED JUMPER.
3

.MUST CONNECT THE 24 VAC COMMON WHEN USING L. THE TERMINAL IS SHOWN AS EQUIPMENT MONITOR, CAN ALSO BE

USED AS A 24 VAC OUTPUT. SEE "HEAT PUMP LED" SECTION FOR MORE INFORMATION.
4

."O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE INSTALLER SETUP

5

.OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE ON SELECT MODELS. WIRES MUST HAVE A CABLE

SEPARATE FROM THE THERMOSTAT CABLE

Fig. 19. Typical hookup of multistage heat pump with no auxiliary/backup heat

(2H/2C heat pump).

32

HEAT PUMP

S1 S2 C R RC W W2 Y2 Y G

S1 S2 C R RC E L Y2 Y G

O/B AUX

OUTDOOR/INDOOR

TEMPERATURE
SENSOR

2

R

C 1

CHANGEOVER

VALVE

FAN RELAY

OPTIONAL
24VAC
COMMON

CONNECTION

5

COMPRESSOR 2

COMPRESSOR 1