Table 11. Sequence of Operation for Heat Pump Systems.

System Setting

Fan Setting

Call for Action

Energize Terminals

Screen Message

Off Auto

None

O/Ba

None

Cool Auto None O/Ba None

Cool or Auto

Auto

Stage 1 Cooling

Y, G, O/B

a

Cool

On

Cool or Auto

Auto

Stage 1 and Stage 2

Cooling

Y, Y2

d

, G, O/B

a

Cool

On

Heat Auto None O/B

a

None

Heat or Auto

Auto

Stage 1 Heating

Y, G, O/B

a

Heat

On

Heat or Auto

Auto

Stage 1 and Stage 2

Heating

Y, AUX

c

, G, O/B

a

Aux Heat On

Heat or Auto

Auto

Stage 1, 2 and 3

Heating

Y, Y2d, AUX

e

, G,

O/B

a

Aux Heat On

Em. Heat

Auto

None

L

b

, O/B

a

None

Em. Heat

Auto

Stage 1 Heating

E, G, Lb, O/B

a

Heat

On

Em. Heat

Auto

Stage 1 and Stage 2

Heating

E, AUX, G, L

b

, O/B

a

Aux. Heat On

a

Configure O/B in Installer Setup. Based on last piece of equipment called (cooling = O or

heating = B).

b

Red LED is on. See LED Indication section for more details.

c

If Installer Setup System Type is set to 2Heat/1Cool Heat Pump with Auxiliary Heat.

d

If Installer Setup System Type is set to 3Heat/2Cool Heat Pump with Auxiliary Heat.

e

This terminal does not energize if Installer Setup System type is set to 2 Heat/2 Cool Heat

Pump with no Auxiliary Heat