Comfort Stat CDT901 User Manual
Page 96
CDT900 Series Touchscreen Programmable Thermostata
Table 11. Sequence of Operation for Heat Pump Systems.
System Setting
Fan Setting
Call for Action
Energize Terminals
Screen Message
Off Auto
None
O/Ba
None
Cool Auto None O/Ba None
Cool or Auto
Auto
Stage 1 Cooling
Y, G, O/B
a
Cool
On
Cool or Auto
Auto
Stage 1 and Stage 2
Cooling
Y, Y2
d
, G, O/B
a
Cool
On
Heat Auto None O/B
a
None
Heat or Auto
Auto
Stage 1 Heating
Y, G, O/B
a
Heat
On
Heat or Auto
Auto
Stage 1 and Stage 2
Heating
Y, AUX
c
, G, O/B
a
Aux Heat On
Heat or Auto
Auto
Stage 1, 2 and 3
Heating
Y, Y2d, AUX
e
, G,
O/B
a
Aux Heat On
Em. Heat
Auto
None
L
b
, O/B
a
None
Em. Heat
Auto
Stage 1 Heating
E, G, Lb, O/B
a
Heat
On
Em. Heat
Auto
Stage 1 and Stage 2
Heating
E, AUX, G, L
b
, O/B
a
Aux. Heat On
a
Configure O/B in Installer Setup. Based on last piece of equipment called (cooling = O or
heating = B).
b
Red LED is on. See LED Indication section for more details.
c
If Installer Setup System Type is set to 2Heat/1Cool Heat Pump with Auxiliary Heat.
d
If Installer Setup System Type is set to 3Heat/2Cool Heat Pump with Auxiliary Heat.
e
This terminal does not energize if Installer Setup System type is set to 2 Heat/2 Cool Heat
Pump with no Auxiliary Heat
95