CDT900 Series Touchscreen Programmable Thermostata

Control Dehumidification Setting (Select

Models)

Select models read the inside humidity level an
allow for a dehumidification setting:
1.Press the More key until the inside humidity
percent and dehumidification setpoint are
shown.

2.Use Up and Down arrow keys, located to
the right of the dehumidifier setpoint, to set
desired humidity level dehumidification in
the summer.
3.Press Done key.

Dehumidification Droop

Control

The dehumidification control attempts to
control to the user's humidity setpoint by
turning on the air conditioner. In extremely
high humidity conditions, the thermostat
keeps the air conditioner running
(energizing Y and G) for up to 3°F below
the temperature setpoint. It does this while
trying to achieve the desired humidity
setpoint and balancing that with the
temperature setpoint. The thermostat
controls up to 3° F below the temperature
setting until either the humidity is satisfied
or conditions change.