CDT900 Series Touchscreen Programmable Thermostata

Installer Setup

Number

Installer Setup

Name

Settings Notes

0510

Humidifier Pad

Replacement

Reminder

0-humidifier pad replacement reminder off
1-90 calendar days
2-180 calendar days
3-365 calendar days

0520

UV Lamp Replacement

Reminder

0-UV lamp replacement reminder off
1-365 calendar days

0530

Adaptive Intelligent

Recovery

1-Adaptive Intelligent Recovery control is
activated (system starts early so setpoint is
reached by start of program period).
0-Conventional Recovery (system starts
recovery at programmed time)

0540 Number

of

Periods

2-two periods available (Wake and Sleep)
4-four periods available (Wake, Leave,
Return and Sleep)

Not shown if non-
programmable isselected. 2 or
4 applies to all days of the
week. (when it is changed, the
sched need to be
reprogrammed)

0580

Minimum Compressor
Off Time

5-five-minute compressor off-time setting
(factory setting)
0, 2, 3, 4-other compressor off-time settings

0600

Heat Temperature
Range Stop

40-90-temperature range (1°F increments) of
heating setpoint.

Shown in 1/2 °C.

0610

Cool Temperature
Range Stop

50-99-temperature range (1°F increments) of
cooling setpoint.

Shown in 1/2 °C.

0640 Clock

Format

12-12 hour clock (factory setting)
24-24 hour clock