CDT900 Series Touchscreen Programmable Thermostata

Table 9. Sequence of Operation for Conventional Systems.

System Setting

Fan Setting

Call for Action

Energize Terminals

Screen Message

Off Auto

None

None

None

Cool Auto None None None

Cool or Auto

Auto

Stage 1 Cooling

Y, G

Cool On

Cool or Auto

Auto

Stage 1 and Stage 2

Cooling

Y, Y2b, G

Cool On

Heat Auto

None None None

Heat or Auto

Auto

Stage 1 Heating

W, Ga

Heat On

Heat or Auto

Auto

Stage 1 and Stage 2

Heating

W, W2c, Ga

Heat On

a

G energizes only if Installer Setup number 0180 is set to Electric.

b

If Installer Setup System type is set to two stages of cooling.

c

If Installer Setup System type is set to two stages of heating.