Cdt900 series touchscreen programmable thermostata, Table 3.installer setup menu.(continues) 51 – Comfort Stat CDT901 User Manual

Page 52

Advertising
background image

CDT900 Series Touchscreen Programmable Thermostata

Installer

Setup

Number

Installer Setup

Name

Settings Notes

0180

Fan Control in Heating

0-gas or oil furnace equipment controls fan in
heating (factory setting)
1-electric furnace thermostat controls fan in
heating

Only shown if conventional
system is selected. If heat
pump is chosen, fan defaults
to electric.

0190

Changeover Valve O/B

Terminal Energized in

Heating or Cooling

(Heat Pumps Only)

0-changeover valve O/B terminal setting
1-changeover valve O/B terminal is
energized in heating

Only shown if heat pump
system is chosen.

0200

Backup Heat Source

(Auxiliary Heat)

0-heat pump backup heat source is electric
(factory setting)
1-heat pump backup heat source is fossil fuel

Only shown if 2 heat/1 cool or
3 heat/2 cool heat pump is
chosen

0210

External Fuel

FossilFuel Kit

0-no external fossil fuel kit is controlling heat
pump backup heat. This thermostat controls
the dual fuel. Must install outdoor sensor and
set Installer Setup Number 0340 to number
2. 1-external fossil fuel kit is controlling heat
pump backup heat

Only shown if fossil fuel is
chosen as backup heat
source.

0220

Cycles per hour (cph)

for 1st Stage

Compressor

3-cph recommended for compressors
(factory setting)

1, 2, 4, 5, 6-other cycle rate settings

0230

Cycles per hour (cph)

for 2nd Stage

Compressor

3-cph recommended for compressors
(factory setting)

1, 2, 4, 5, 6other cycle rate settings

Only shown if two stages of
cool are selected.

Table 3.installer Setup Menu.(CONTINUES)