CDT900 Series Touchscreen Programmable Thermostata

1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED
2. FACTORY INSTALLED JUMPER.
3

OUTDOOR SENSOR REQUIRED IN SYSTEM WITH FOSSIL FUEL BACKUP HEAT THAT IS NOT USING AN EXTERNAL FOSSIL FUEL KIT

4

OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE FROM THE

THERMOSTAT CABLE

5

MUST CONNECT THE 24 VAC COMMON WHEN USING L. THE TERMINAL IS SHOWN AS EQUIPMENT MONITOR, CAN ALSO BE USED AS

A 24 VAC OUTPUT. SEE "HEAT PUMP LED" SECTION FOR MORE INFORMATION.

6

."O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE INSTALLER SETUP.

Fig. 20. Typical hookup of single-stage heat pump with auxiliary/backu

heat (2H/1C heat pump).

33

3

4

HEAT PUMP

S1 S2 C R RC W W2 Y2 Y G

S1 S2 C R RC E L Y2 Y G

O/B AUX

OUTDOOR/INDOOR

TEMPERATURE
SENSOR

2

R

C 1

CHANGEOVER

VALVE

FAN RELAY

OPTIONAL
24VAC
COMMON

CONNECTION

6

5

COMPRESSOR

RELAY

EMERGENCY
HEAT RELAY

HEAT 2 RELAY

(AUXILIARY HEAT)

EQUIPMENT

MONITOR