CDT900 Series Touchscreen Programmable Thermostata

Table 3.installer Setup Menu. (CONTINUES)

Installer Setup

Number

Installer Setup

Name

Settings Notes

0240

Cycles per hour (cph)

for 1st Stage

Conventional Heat

1- 1 cph used for steam and gravity
3-3 cph used for hot water system and high

efficiency (90% or better) furnaces
5-5 cph used for standard fossil fuel forced
air (less than
80% efficient) systems (factory setting)
9-9 cph used for electric furnaces
2, 4, 6, 7, 8, 10, 11, 12other cycle rate
settings

Not shown if system selection
is heat pump. Selection in this
stage changes default cph for
2nd stage heat.

0250

Cycles per hour (cph)

for 2nd Stage Heat

(Aux Heat for 2H/1C

Heat Pumps)

1-1 cph used for steam and gravity
3-3 cph for hot water systems and high
efficiency (90% or better) furnaces
5-5 cph for standard fossil fuel forced air

(less than 90% efficient) systems (factory
setting)
9-9 cph used for electric furnaces or electric
auxiliary heat for heat pump systems
2, 4, 6, 7, 8, 10, 11, 12other cycle rate
settings

Only shown if two stages of
heat are selected.

0260

Cycles per hour (cph)

for 3rd Stage Heat Aux

Heat for 3H/2C Heat

Pumps)

1-1 cph used for steam and gravity
3-3 cph for hot water systems and high
efficiency (90% or better) furnaces
5-5 cph for standard fossil fuel forced air
(less than 90% efficient) systems (factory
setting)
9-9 cph used for electric furnaces or electric
auxiliary heat for heat pump systems
2, 4, 6, 7, 8, 10, 11, 12-other cycle rate
settings

Only shown if 3H/2C heat
pump is selected.