Comfort Stat CDT901 User Manual

Page 54

Advertising
background image

CDT900 Series Touchscreen Programmable Thermostata

Table 3.installer Setup Menu. (CONTINUES)

Installer Setup

Number

Installer Setup

Name

Settings Notes

0270

Cycles per hour (cph)

for Emer

3-3 cph for hot water systems and high
efficiency (90% or better) furnaces

5-5 cph for standard fossil fuel forced air
(less than 90% efficient or better) systems

9-9 cph for electric strip heat for heat pumps

Only shown if 2H/1C or 3H/2C
heat pump is selected.

0280 Continuous

Backlight

0-Backlight function disable

1-Backlight function enable

.

0300 Changeover

0-manual changeover (factory setting)

1-auto changeover

0310 Deadband

Heating and cooling setpoints can be set no
closer than chosen value:

2-2°F (1.5°C)

3-3°F (2°C)

4-4°F (2.5°C)

5-5°F (3°C)
6-6°F (3.5°C)

7-7°F (4°C)

8-8°F (4.5°C)

9-9°F (5°C)

Shown only if automatic
changeover is selected.

0320

Temperature Indication

Scale

0-fahrenheit temperature display (factory
setting)

1-celsius temperature display

when it is changed, the sched

need to be reprogrammed)

53