Cdt900 series touchscreen programmable thermostata, Table 3.installer setup menu. (continues) 58 – Comfort Stat CDT901 User Manual

Page 59

Advertising
background image

CDT900 Series Touchscreen Programmable Thermostata

Installer Setup

Number

Installer Setup

Name

Settings Notes

0690

Temperature Control in
Cool

1-less aggressive temperature control (could
cause temperature undershoot)
2-Standard temperature control in cooling
(factory setting)
3-more aggressive temperature control
(could cause temperature overshoot)

Applies to recovery ramp.
Choose 1 if getting
temperature overshoot.
Choose 3 if getting
temperature undershoot.

0700

Temperature Display
Offset

-3°F (-1.5°C)
-2°F (-1°C)
-1°F (-.5°C)
0°F (0. °C) (no difference in displayed
temperature and actual room temperature )
1°F (.5°C)
2°F (1°C
3°F (1.5°C)

0710 Reset

Thermostat

0-no thermostat reset.
1-resets all Installer Setup Options to default
values and resets schedule to default setting.

Only calendar settings and
time are retained.


Table 3.installer Setup Menu. (CONTINUES)

58

Advertising
This manual is related to the following products: