Burkert Type 8691 User Manual

Page 21

Advertising
background image

21

Installation

2. installation of the masking ring and the control head

Masking ring

Guide rail

Puck

Figure 11:

Installation of the

masking ring and

aligning the puck

Pull the masking ring onto the actuator cover (for actuator sizes ∅ 50 and ∅ 63 only).

noTe!

Damaged printed circuit board or malfunction.

▶ Ensure that the puck is situated flat on the guide rail.

Push the control head onto the actuator. The puck must be aligned in such a way that it is inserted into the
guide rail of the control head.

Press the control head all the way down as far as the actuator and turn it into the required position.

Fastening screws

max. 0.5 Nm

Figure 12:

Installation of the control head

Ensure that the pneumatic connections of the control head and those of the valve actuator are situated
preferably vertically one above the other (see “Figure 13”).
If they are positioned differently, longer hoses may be required other than those supplied in the accessory kit.

noTe!

too high torque when screwing in the fastening screw does not ensure degree of protection ip65 /
ip67.

▶ The fastening screws may be tightened to a maximum torque of 0.5 Nm only.

Attach the control head to the actuator using the two side fastening screws. In doing so, tighten the fastening
screws hand-tight only (maximum torque: 0.5 Nm).

english

Type 8691

Advertising