English – Burkert Type 8035 User Manual

Page 15

Advertising
background image

15

Installation

Type 8025/8035 /

Table 1: Flow rate/ fluid velocity/ DN of S020 fitting and of S030 sensor-fitting diagram

S020 fitting

0.1

0.3 0.5

1

3 5

10

0.01

0.02

0.05

0.1

0.2

0.5

1

2

5

10

20

50

100

200

m

3

/h

0.2

0.5

1

2

5

10

20

50

100

200

500

1000

2000

3000

l/min

0.3 0.5 1

3 5

10

30

m/s

fps

US gpm

0.05

0.1

0.2

0.5

1

2

5

10

20

50

100

200

500

1000

DN 65
DN 50 (DN65)*
DN 40 (DN50)*
DN 32 (DN40)*

DN 25 (DN32)*

DN 20 (DN25)*

500

1000

2000

2000

5000

10000

5000

20000

5000

10000

20000

30000

50000

100000

DN 400

DN 350

DN 300

DN 250

DN 200
DN 150

DN 125
DN 100
DN 80

Flow rate

Flow velocity

Example

1)

S030 sensor-fitting

0.1

0.3 0.5 1

3 5

10

0.01

0.02

0.05

0.1

0.2

0.5

1

2

5

10

20

50

100

200

m

3

/h

l/min

0.3 0.5 1

3 5

10

30

m/s

fps

gpm

0.05

0.1

0.2

0.5

1

2

5

10

20

50

100

200

500

1000

DN65

DN50 (DN65)*
DN40 (DN50)*

DN32 (DN40)*

DN25 (DN32)*
DN20 (DN25)*
DN15 (DN15 / DN20)*

DN08

DN06

0.2

0.5

1

2

5

10

20

50

100

200

500

1000

2000

3000

Example

Flow rate

Flow velocity

Example:

• Specification: if the nominal flow

rate is 10 m

3

/h, the ideal flow

velocity is between 2 and 3 m/s.

• Solution: intersection between

flow rate and flow velocity in the
graph gives the appropriate pipe
diameter, DN40 (or DN50 for
the asterisked fittings).

1)

The device cannot be installed

onto the following DN20 fittings:
* For the fittings:
• with external threads acc. to

SMS 1145.

• with weld ends

acc. to SMS 3008,
BS 4825 / ASME BPE or
DIN 11850 Rg2.

• Clamp acc. to

SMS 3017 / ISO 2852,
BS 4825 / ASME BPE or
DIN 32676.

English

Advertising