Wiring

Type 8025/8035 /

8.4.6. Wiring the 8025 compact version and the 8035, 115/230V Ac, without relays, with

cable glands

Before wiring the device, configure the selectors on the electronic board (see chap. "8.3").

Supply

12..36Vdc

FLOW SENSOR

COIL

NPN

SOURCE SINK

L+

L-

PE

P-

P+

NC

L+

L-

PE

P-

P+

Iout

PULSE

OUTPUT

Without

With

Relays

N

PE

L

230V

T 125 mA

{

3

7

8

9

6

5

4

A

2

1

B

C

PE

Switch A : see chap. "8.3.1"

Switch B : see chap. "8.3.3"

Switch C : see chap. "8.3.2"

terminal block 1
lout: 4-20 mA output
L+ (red wire, factory wired)
L- (black wire, factory wired)
PE: wiring of the PE between the main board and the protection board
P-: negative pulse output
P+: positive pulse output

terminal block 2 pe
Shield connection (green/yellow wire, factory wired)
connector 3: connection of the flow sensor
terminal block 4: wiring of relay 1, see chap. "8.4.2"
terminal block 5: wiring of relay 2, see chap. "8.4.2".
Jumper wire 6: jumper wire to be removed if the 4-20 mA output is
connected
time-delay fuse 7: fuse to protect the 115 V AC or 230 V AC
power supply
terminal 8: earth terminal, internally connected to the earth plug
terminal block 9: wiring of the 115/230 V AC power supply

Fig. 32: Terminal assignment of a 115/230 V AC compact version, with relays, with cable glands