Around the device (see "fig. 6") – Burkert Type 8035 User Manual

Page 17

Advertising
background image

17

Installation

Type 8025/8035 /

Correct

flow direction

Incorrect

Correct

Incorrect

Fig. 6: Air bubbles within the pipe

If necessary, use a flow conditioner to improve measurement
accuracy.

7.2.2. installation of the 8025 on the s020

fitting

2

1

3

4
5

6

Install the S020 fitting into the pipe
obeying the instructions in chap. "7.2.1"

Check that there is a seal on the fitting
and that it is not damaged. Replace the
seal if necessary.

Insert nut 3 on fitting 5.

Insert snap ring 2 into groove 4.

Check that seal 6 is correctly inserted on
the flow sensor.

Insert device 1 into the fitting.

If the mounting is correctly done the device
cannot be turned around anymore.

Hand lock the assembly with nut 3.

Fig. 7: Installation of the 8025 on the S020 fitting

English

Advertising
This manual is related to the following products: