Burkert Type 8035 User Manual

Page 19

Advertising
background image

19

Installation

Type 8025/8035 /

Seal

Nut

Washer

Screw

Cable clip

Fig. 10: Installation of a panel version of the 8025

Insert the 4 screws in the housing (from the front). Use the 4
supplied M4*25 screws if the cabinet door is too thick.

Insert the seal on the external threads of the 4 screws (rear of
the housing).

Put the assembly on the cutout, electronics turned to the inside
of the cabinet.

Put the 4 washers on the 4 screws.

Put a nut on each of the 4 screws and tighten the nuts to secure
the device to the cabinet.

Wire according to the instructions in chapter "8".

7.4.

installation of a wall-mounted
version of the 8025 flowmeter

note

risk of material damage if the cable glands are not tightly
screwed on the housing
• Before installing the wall-mounted housing on its support,

tighten the nuts of the entry item of the cables glands at a torque

of 1.5 Nm.

The flow transmitter in a wall-mounted version has 4 holes in the
bottom of the housing.

Remove the blanking strips covering the screws.

Blanking strips

ENTER

0....9

FLOW

Nut of the entry item

Loosen the 4 screws and open the cover to get access to the
holes [1].