9

Technical data

Type 8025/8035 /

Fluid pressure (compact ver-
sions)



• 8025 compact
• 8035 with S030 fitting in

plastic

• 8035 with S030 fitting in metal

The fluid pressure may be
restricted by the fluid tem-
perature, the material the flow
sensor is made of (only for the
compact 8025) and the material
the fitting used is made of. See
"Fig. 2" and "Fig. 3".

• PN10
• PN10

• PN16 (PN40 on request)

Flow rate measurement

• Measurement range

- Sensor with pulse output

(Hall)

- Sensor with a sinus output

(coil)

• Accuracy

- with a teach-in procedure

- with the K factor of the

fitting used

• Linearity

1)

• Repeatability

1)

- 0.3 m/s to 10 m/s

- 0.5 m/s to 10 m/s

- 1 % of the measured value

(at the value of the teach-in
flow rate)

- 2,5 % of the measured

value

• ±0,5 % of the full scale
• ±0,4 % of the measured value

1)

Determined in the following reference conditions: medium = water, water

and ambient temperatures 20 °C, min. upstream and downstream distances
respected, appropriate pipe dimensions

10

9
8
7
6
5
4
3
2
1
0

-15

0

+20

+40

+60

PVDF

PVDF (PN10)

PVC (PN10)

PP (PN10)

PVC + PP

11

P (bar)

T (°C)

+80

A

Metal

A: range of use

Fig. 2: Fluid temperature /pressure dependency curves for the

8025 compact version, depending on the material the
S020 fitting is made of