Installation and commissioning

Type 8025/8035 /

9.

insTAllATion AnD
commissioninG

9.1.

safety instructions

Warning

risk of injury due to non-conforming operating.
Non-conforming operating could lead to injuries and damage the
device and its surroundings.
• The operators in charge of operating must have read and under-

stood the contents of this manual.

• In particular, observe the safety recommendations and intended use.
• The device/installation must only be operated by suitably trained

staff.

Warning

danger due to non-conforming commissioning.
Non-conforming commissioning could lead to injuries and damage
the device and its surroundings.
• Before commissioning, make sure that the staff in charge have

read and fully understood the contents of the manual.

• In particular, observe the safety recommendations and intended use.
• The device / the installation must only be commissioned by suit-

ably trained staff.

• Before commissioning, set the K Factor of the fitting used. See

chap. "9.6".

9.2.

operating levels of the device

The device has two operating levels: the Process level and the Con-
figuration level.
Table 4: Default settings of the device

function

default value

LANGUAGE

English

UNIT of the flow rate

L/min, 1 decimal

UNIT of the totalizers

L

Number of decimal positions 1
4 mA current output

0.000

20 mA current output

100.0

K FACTOR

51.20

FILTER

5

Value of a pulse (PU)

00.05

Unit of the pulse output

L

Relay 1-

40.0

Relay 1+

50.0

Relay 1 inverted

no

Relay 2-

80.0

Relay 2+

90.0

Relay 2 inverted

no