Wiring instructions, English – Burkert Type 8035 User Manual

Page 26

Advertising
background image

26

Wiring

Type 8025/8035 /

Table 3: Positioning of the Source / Sink selector depending on

the wiring of the current output of a version with relays

Wiring the 4-20 mA output position of the source/sink

selector on a version with relays

Not wired (jumper wire in
place)

SOURCE

Sourcing mode

SOURCE

Sinking mode

SINK

8.3.3. 115/230 V Ac selector
The 115/230 V AC selector makes it possible to configure the
supply voltage of the device in a 115/230 V AC version.

230V

115V

Energize the
device with
a 230 V AC
voltage.

Energize the
device with
a 115 V AC
voltage.

Fig. 20: Selector of the supply voltage on a 115/230 V AC version

8.4.

Wiring the 8025 in compact
version and the 8035, with or
without relays, with cable glands

8.4.1. Wiring instructions

Seal the unused cable gland using the stopper gasket sup-
plied to make sure the device is tight.

Unscrew the nut of the cable gland.

Remove the transparent disc inside the cable gland.

Insert the stopper gasket.

Screw the nut back.

Lift the transparent lid after having unfastened the screw.

Untighten the 4 screws then remove the cover from the device.

For the versions with relays, insert the cable clip.

Supply

12..36Vdc

FLOW SENSOR

COIL

NPN

SOURCE SINK

L+

L-

PE

P-

P+

NC

L+

L-

PE

P-

P+

Iout

PULSE

OUTPUT

Without

With

Relays

PE

English

Advertising
This manual is related to the following products: