APPENDIX A: M–TRAVERSE

SPECIFICATIONS

Job Space

536,000,000 Encoder Lines Maximum

Accuracy:

+ 1 Encoder Line Resolution

Response:

1 millisecond control loop update

Tuning:

Separately adjustable Gain and Integral parameters for
stability and response

Scaling Formats:

Direct - Direct set of Speed Command Out (analog)
Follower - Ratio Setpoint calculation

Setpoints:

Six Total:
(4) Engineering Units
(1) Jog
(1) Direct

Frequency Inputs:

Feedback and Lead
Quadrature Encoder Format
Open-Collector Driver Compatible (NPN)
Internal 2.7 kOhm to +5 VDC on M–Traverse
120 kHz maximum frequency

Preset Select:

External switch selection of four preset engineering unit
setpoints

Discrete Inputs:

Vin, MAX < 24.0 VDC
Vin, LOW < 0.7 Volts minimum
Vin, HIGH > 4.3 Volts maximum
Home Sync
Setpoint Select A
Setpoint Select B
Home Set
Home Seek
Home Return
Batch Reset
Run
Wait
F-Stop
Keypad Lockout