CONTREX M-Traverse User Manual

Page 70

Advertising
background image

3 - 23

Table 3-14 Default Control Parameters for Changes

CP

Parameter Name

Parameter Value

CP-24

Edge/Center Based

1

CP-25

Change Activation

1

CP-30

At-Home Band

4

CP-31

Home Offset

0

Table 3-15 Entering Control Parameters for Changes

CP

Parameter Name

Parameter Value

CP-24

Edge/Center Based

Enter “1” for an edge based profile.
Enter “2” for a center based profile.

CP-25

Change Activation

When CP-24 is set to “1” (edge based), then:
Enter “1” to activate changes when the Follower is in
the “Home position.
Enter “2” to activate changes immediately.
Enter “3” to activate changes when the Follower is in
the end dwell position.

CP-30

At-Home Band

Enter the number of encoder lines that you want to
allow on either side of the “0” Home Set position.

CP-31

Home Offset

If CP-24 is set at “1” (edge based), enter the distance
from the sensor to the desired position of “Home”.
If CP-24 is set at “2” (center based), enter the distance
from the sensor to the center of the web.