CONTREX M-Traverse User Manual

Page 88

Advertising
background image

3 - 41

The factory defaults for the Output B Control Parameters are found in Table 3-34. To
modify the default parameters refer to Table 3-35. If you are uncertain how to enter a
Control Parameter, review the

Operations: Keypad

section.

Table 3-36 Default Control Parameters for Output B

CP

Parameter Name

Parameter Value

CP-93

Output B Segment

1

CP-94

Output B Direction

0

CP-95

Output B Polarity

0

Table 3-37 Entering Output B Control Parameters

CP

Parameter Name

Parameter Value

CP-93

Output B Segment

Enter “1” to activate Output B during the constant pitch
plateau segment of the Follower profile.
Enter “2” to activate Output B during the constant pitch
plateau and Accel/Decel segment of the Follower profile.
Enter “3” to activate Output B during the Dwell
segment of the Follower profile.

CP-94

Output B Direction

Enter “1” to activate Output B during the forward
direction.
Enter “2” to activate Output B during the reverse
direction.
Enter “3” to activate Output B during the forward and
reverse directions.

CP-95

Output B Polarity

Enter “0” to activate Output B as Active Low Voltage
Level.
Enter “1” to activate Output B as Active High Voltage
Level.