Cp-26 batch format – CONTREX M-Traverse User Manual

Page 167

Advertising
background image

5 - 20

If CP-25 is set to “1” then all of the changes will occur when the Follower is at “Home”.

If CP-25 is set to “2” and either the Accel/Decel Length or Dwell parameters are changed, the
changes will only occur at “Home”.

If CP-25 is set to “2” and the setpoint speed is changed (either faster or slower), the change will
occur immediately, but only if the change occurs within the new constant pitch plateau of the
profile. Otherwise setpoint speed changes occur at “Home”.

If CP-25 is set to “2” and the traverse length is changed, the change will occur immediately, but
only if the longer change occurs within the old constant pitch plateau and a shorter change
occurs within the new constant pitch plateau of the profile, and either change is in a forward
direction. Otherwise traverse length changes occur at “Home”.

If CP-25 is set to “2” and both the traverse length and the setpoint speed are changed, then use
the switches to make the changes and stay within the profile parameters listed above for setpoint
speed and traverse length changes. When any of the changes are not within the specified
plateaus of the profile, then the changes will occur when the Follower mechanism reaches
“Home”. Refer to the diagrams below.

Setpoint Changes

accel/decel

accel/decel

Dwell

New

Plateau

Faster

Slower

New

Plateau

Traverse Length

Changes

accel/decel

accel/decel

Dwell

New

Plateau

Shorter

Longer

New

Plateau

If CP-25 is set to “3”, the change will occur at the next forward or reverse dwell position.
However, if there is no dwell position, a setpoint change will occur at the start of the reverse
plateau in the forward direction or at the start of the forward plateau in the reverse direction. If
the setpoint is changed to a slower speed, this change will cause a spike, which will momentarily
cause an abrupt jolt to the Follower mechanism. Therefore, for a smooth operation, is best to
specify a Dwell (CP-10) parameter.

CP-26

BATCH FORMAT

Use the Batch Format (CP-26) parameter to indicate which type of count that you want the Batch
Counter to do. You can count either Follower traverses or Lead reel revolutions. Enter “1” in
CP-26 to count the Follower traverses. Enter “2” in CP-26 to count Lead revolutions.