CONTREX M-Traverse User Manual

Page 179

Advertising
background image

5 - 32

CP-73 CONTROL MASK

The Serial Communications can control some of the discrete input functions. Enter the number
for the required functions, as listed below.

0 = F–Stop only
1 = F–Stop, Run, Home Return, Home Seek, Home Set
2 = F–Stop, Batch Reset, Setpoint Select 1-4
3 = All of the Above

MV-74 COMMUNICATIONS ERROR

Serial Communications Error identifies errors in the last transmitted message that was sent to
the M–Traverse by the host computer. The digit that displays a number “1” indicates the error.
In the example below, “Invalid Parameter Code” is the error.

Transmit Error (parity, framing, overrun, no ETX, no STX)

Parameter Error (invalid parameter code or message type)

Data Error (invalid data)

Min-Max Error (out of range)

Control Mask Error or Lockout during Run State

Not Used

CP-79 KEYPAD LOCKOUT MASK

Keypad Lockout Mask is active when the Keypad Lockout input (J4, pins 10,11) is closed. The
value that you enter in CP-79 determines which CPs are locked out and inaccessible to the
operator. Enter the number for the required format, as listed below.

1 = All CPs are locked out (Global lockout).
2 = All CPs except 01-08 (Setpoints and Traverse Lengths) are locked out.

MV-80 LEAD JOB SIZE

The Lead Job Size displays the total Lead encoder lines that are registered for the most recent
job cycle.

Advertising