2.7 An experienced, qualified heating contractor must install this heater and

system.


2.8 This heater is not designed for attachment or use with ductwork (unless a

ductable model has been purchased).


2.9 This heater is designed to burn the following approved fuels:

Used 10W through 50W Crankcase Oils

Used Automatic Transmission Fluid

No. 1 and No. 2 Fuel Oils

2.10 Do not attempt to start the burner when excess oil, oil vapor, or fumes

have accumulated! Never press the red button on the oil primary
control more than twice! This could cause excess vapor, or fuel to
ignite causing damage to the heater and/or chimney.


2.11 Do not store or use gasoline, or any other flammable liquid and/or vapors

near this heater.


2.12 This heater is not designed for use in hazardous atmospheres such as:

Paint Shops, Feed Mills, installations where explosive, or flammable
conditions are present or could occur.


2.13 WARNING!

Lanair heaters rely on natural draft. Down drafts (positive pressures) in the
heaters chimney will occur in buildings where negative pressures are
created by exhaust fans, (car exhaust, paint booths, etc). Do not try to use
a power vent to overcome a down draft (positive pressure). An adequate
make-up air system is required when exhaust fans are used (consult your
heating contractor).