Note: Any abuse or neglect of the pump will void its warranty. The maintenance
schedule may be more frequent depending on the type of oil and the severity of the
contamination. Refer to “General Information” in the owner’s manual.

Operation Requirements


1.

Oil in the supply tank must not be below 35º F and indoors.

2.

Do not operate the supply pump with plugged filter/strainers.

3.

Keep the fuel supply tank half full at all times to avoid running the pump dry.

4.

Strain all used oils with a 100-mesh strainer before pouring into the supply tank.

5.

The supply pump is designed for pumping used oil 10W-50W, automatic
transmission fluid, and No. 1 & No. 2 fuel oil.
CAUTION: The use of any other fuels will void the warranty.

6.

Use a tank that is UL Listed for the storage of oil, such as the Lenan 195 gallon
storage tank.

7.

If you lose oil output from the supply pump, clean the filter/strainer, check for
loose pipe fitting, and low fuel levels in your tank. Re-prime your pump. Follow
the priming instructions, and restart the furnace.