TOP INSTALLATION ERRORS

Using the wrong size of supply lines, suction line, or overflow lines. Using

anything but a straight run back to the tank on the overflow (NO elbows or

horizontal runs of any kind.).

(See the owner’s manual)

Not using Class “A” chimney when passing through a combustible or to the

outside. Single wall and Class “B” Gas Vent are not safe.

(See the owner’s manual)

Not installing or setting the barometric damper on the chimney.

(See the owner’s manual)

Not installing a capped clean out tee on the chimney.

(See the owner’s manual)

Not having a long enough vertical run of chimney from the capped clean

out tee to the rain cap. Installing to many 90° elbows (each elbow equals

10’ of run. Max. run 30’).

(See the owner’s manual)

Questions or Comments? Call LENAN’S Service

Department (800) 753-1601