Top operation errors – Lanair HI320 User Manual

Page 88

Advertising
background image

TOP OPERATION ERRORS

Not using the flame observation view port on the side of the heater to VISUALLY

SET THE FLAME. (See page 26AA of the owner’s manual)

Over firing the heater by using incorrect oil and air pressures. VISUALLY SET

THE FLAME see page 26 AA in owner’s manual. Flame tips should be no more

than 3/4 of the way into the combustion chamber.

Not using proper fuel management with the waste oil fuel. Pre-straining all fuels

and draining water form the tank weekly. (See the owner’s manual)

Using non-recommended fuels. (See the owner’s manual)

Not checking the barometric damper setting for the venting of exhaust gases.

(See the owner’s manual)

Failure to clean the heat exchanger/combustion chamber. (See owner’s manual

Section 20)

Failure to clean and maintain the burner. (See owner’s manual)

Questions or Comments? Call LENAN’S Service

Department (800) 753-1601

Advertising