Lanair HI320 User Manual

Page 61

Advertising
background image

SUPPLEMENTAL TROUBLESHOOTING GUIDE

Chart #1

Symptom

Possible Cause

Corrective Action


A. Burner will not start.

1. Main power turned off,

1. Check disconnect.

or disconnected.

Using a multi-meter

make sure you have
120 V at junction box.


2. Thermostat defective

2. Re-install thermostat.

Make sure thermostat

is installed properly

(See Page # 17).


3. Oil Primary defective or

3. Test oil primary, or

safety switch of oil primary.

reset.

Chart #2 & #3


B. Burner attempts to fire,

1. Fuel supply low, or

1. Fill supply tank if low.

and has a poor flame,

contaminated.

Drain if contaminated.

or no flame.

2. Supply pump defective or

2. Test supply pump,

improperly installed.

check fuel lines for

No fuel to the nozzle.

suction leaks. Install

supply pump and
supply lines as per

page #11 to #13c.


3. Air regulator or air solenoid

3. Test air regulator, and

defective.

solenoid, if defective

replace.


4. Ignition transformer

4. Test transformer should

defective.

have 120 V input, and

10,000 V output (metal

case) 14,000 V (plastic

case).


5. Air preheater diaphragm

4. Clean air preheater

defective.

and replace diaphragm.







Page 44