SecurityMan Air-AlArmII series - User manual User Manual

Page 15

Advertising
background image

• Service life: ≤2 years
• Alarm Distance: <4cm

Installation and Usage:
To install the Smart door/window sensor, mount the magnetic and the emitting of the sensor to the door frame about
5~6 feet above ground. Maker sure the magnetic is installed on the apposite side of the battery compartment of the
emitting piece of the Smart sensor. Mount it high enough to prevent children from tampering with the sensor. Use the
clear plastic rectangular bracket underlay provided to mount if surface area is un-even. When mounting the magnetic
and the emitting pieces of the Smart sensor ensure that the spaces or gaps in between the two pieces are within 1/4” of
an inch (10mm). Insert the battery included into the battery compartment of the sensor. Replace battery if the blue LED
light on the sensor is frequently flashing.

Using the smart door/window sensor:
By default, the Smart door/window sensor is programmed to zone 6 of the alarm host unit. Programming the Smart
door/window senor to the alarm host is not necessary unless the sensor is not working properly and accordingly to the
alarm host. In this case it is necessary to follow the “To Add” procedures under the “Adding and Canceling Smart Door/
Window Sensor” below.

The smart door/window sensor featured the Smart Arm. Smart Arm detect the OPEN status alert of the door/window
when attempting to ARM the alarm system. The Smart Arm by default is enabled and dedicated for zones 06 through 10.
When attempting to Arm the door/window while the door/window is opened, the alarm host will beep 3 times in series
of 8 times and the blue LED light flash each time there is a beep to notify you that the door/window is opened in the
indicated zone (s) until one of the following action is taken:

1) Force alarm to Arm by pressing the ARM button 2 times to ignore the door/window OPEN status alert and Arm the
alarm system. The opened door/window can be close at anytime to complete the arming process for the given Zone
Alert. Please be noted if the door is still open and never close after forcing the system to Arm, then that door/window
sensor will NOT be active to set off the alarm.
2) Close the door/window in the indicated zone(s) of the main panel first and then Arm the alarm host.

**Smart Arm feature beep 3 times in series of 8 times plus the zone(s) LED light and the door/window LED light
flashes with each series of beep.

**Arming the alarm system when the door/window is opened will not be successful unless one of the two actions

listed above is taken.

enabling and Disabling smart Arm (smart door/window sensor sM-87l and host sM-8088T)

Enabling Smart Arm (Default):

Press

PrGM + Password + enT + 91 + enT

11

Advertising