SecurityMan Air-AlArmII series - User manual User Manual

Page 9

Advertising
background image

01: Group 1 (personal telephone number)
02: Group 2 (personal telephone number)
03: Group 3 (personal telephone number)
04: Group 4 (personal telephone number)
05: Group 5 (personal telephone number)
06: Group 6 (reserved for CID Protocol number for management center, not for personal numbers, requires monthly fees)
*** To delete or reset the telephone enlisted number press, “PRGM+password+ENT+XX+ENT+ENT” (XX is the group
number, ie. 01, 02, etc.)

Delay Time to Arm: PrGM + Password + enT + XX + enT_ _ Setup a dwell time in which the alarm will become activated or
armed. Enter 10 for XX to setup Delay Time to Arm for 40 seconds, enter 11 to setup Delay Time to Arm for 1 minute and press
the ENT button to confirm. The default setting is 10 or 40 seconds alarm dwell time. If armed, any wireless triggers within the
dewll time of 40 seconds or 1 minute, the Alarm Host will beep twice.

Delay Time to Alarm: PrGM + Password + enT + XX + enT__ Setup a dwell time in which the alarm will sound or trigger. Enter 20
for XX to setup immediate alarm sound triggering, enter 21 to setup a 15 seconds Delay Time to Alarm. The default setting for
Delay Time to Alarm is 20.

emergency Alarm sound: PrGM + Password + enT + XX + enT_ _Enter 30 for XX to disable Emergency Alarm Sound, enter 31
to setup audible alarm sound, the default is 31. During the Emergency Alarm Sound is disabled or set to 30; the alarm host will
operate normal, and will continue to dial the enlisted phone numbers in case of emergency.

Alarm sound for 1st and 2nd defense line: PrGM + Password + enT + XX + enT_ _ Enter 40 for XX to disable alarm sound for
1st & 2nd defense line, enter 41 to enable Audible alarm, the default is 41. When the Alarm Sound is disabled or set to 40; the
alarm host will operate normal and will continues to dial the enlisted phone numbers upon alarm trigger.

Telephone Disconnection Alarm: PrGM + Password + enT + XX + enT_ _ Enter 60 for XX to disable Telephone Disconnect
Alarm, enter 61 to enable Telephone Disconnect Alarm, the default is 61. Telephone Disconnection Alarm is line of integrity
alarm. That chirps every 5 seconds when the telephone line is not connected to the TEL IN port of the alarm host panel. To
disable the chirping when the telephone is not plugged in to the host; press, “PRGM+password+ENT+60+ENT”.

press PRGM + 888 + ENT followed by 11 + ENT. The programming default password is 888 (3 digits long), and 11 is the
programming code for 1 minute Delay Time to Arm.

Inputting Alarm Telephone number: PrGM + Password + enT + XX + enT + Telephone number + enT_ _ XX indicates
telephone group number which can be programmed with personal or management center phone number. Depending on the
land line service provider a 1 and or area code may be necessary. See group details below:

5

Advertising