Problems

Possible Cause

Solutions

The alarm host sounded off immediately

after connecting the power

The telephone incoming line has not

been connected, poor connection or

short circuit.

Double check, test and secure the incoming telephone line

or use a standard phone to test the line to ensure working

status.

The alarm host cannot record or partially

records

The Record buttons not pressed down

and held while attempting to record, or

not held down all the way.

Securely press and hold down the RECORD button during

recording. Speak up close to the rear speaker of the host.

Repeatedly receiving the alarm telephone

No one picked up the alarm calls or

failure to press the * star button to end/

drop the call.

After answering the alarm phone calls and hearing the

recorded message: please advanced to page 7 (Telephone

Alarm

) of this user’s manual as a reference to try to resolve

this problem, or simply press the * star button to end the

call.

The alarm host does not sound the

alarm after the detector triggered the

alarm in armed mode.

1. The wireless devices may not have

synchronized with the alarm host.

2. The dwell time for Entry Delay or Exit

Delay has not been reached.

1. In “Home” mode, make sure the sensor or wireless devices

triggering is not in the 2nd Defense Line. Simply cancel the

wireless devices and add them in again to synchronize with

the host.

2. Ensure the sensor detectors are not active within the

system setup Entry Delay Time or Exit Delay Time, default

delay time is 40 seconds

The PIR motion sensor does not work

Weak battery power, not switched on,

or the PIR motion detector is in the

power-down mode

Open the sensor shell to install the battery and slide the

power switch to “On”. Power down mode may be in affect:

“5S”: detect once every 5 seconds “5MIN”: detect once every

5 minutes, please refers to the user’s manual for PIR setup.