IAI America MSEP User Manual

Page 115

Advertising
background image

3.4 Fieldbus

Type
Address Map

107

3.4.4

Control Signals for Positioner 1/Simple Direct Mode

Caution: This mode is not applicable for CompoNet and MECHATROLINK.

To select the mode, use Gateway Parameter Setting Tool. All the modes can be used only by

indicating a position number.



Positioner 1 Mode : Operation is performed by indicating a position number from the operation

modes of the position data set in the position table.

Simple Direct Mode : This is a mode to operate with inputting the target position for positioning

directly. Except for the target position, the operation follows the position

data set in the indicated position number.


The settable No. of position data items is max 256 points.

The main functions of ROBO Cylinder capable to control in this mode are as described in the

following table.



{

: Direct control

ٌ

: Indirect control

u

: Disabled

ROBO cylinder

function

Positioner 1

Mode

Simple

Direct Mode

Remarks

Home-return

operation

{

Positioning operation

ٌ

{

Positioner 1 Mode : These items must be set

in the position data table.

Simple Direct Mode : For those other than the

target position, it is

necessary to set the

position data.

Speed and

acceleration/

deceleration setting

ٌ

These items must be set in the position data

table.

Pitch feed

(incremental)

ٌ

These items must be set in the parameters.

Pressing operation

ٌ

Speed change during

movement

ٌ

Operation at different

acceleration and

deceleration

ٌ

These items must be set in the position data

table.

Pause

{

Zone signal output

ٌ

Zones are set using parameters.

PIO pattern selection

u


(1) PLC Address Composition

(m is PLC input and output top word address for each axis number)

PLC ĺ MSEP (PLC Output)

MSEP ĺ PLC (PLC Input)

Target Position

(Note 1)

m to m+1

Current Position

m to m+1

Specified Position No.

m+2

Completed Position No.

(Simple Alarm Code)

m+2

Control Signal

m+3

Status Signal

m+3

[Refer to Section 3.4.2 for the address maps for each Fieldbus.]


Note 1

For Positioner 1 Mode, it is unnecessary to indicate the target position with a value. It will be

disregarded even if written in.