4 fieldbus type address map – IAI America MSEP User Manual

Page 123

Advertising
background image

3.4 Fieldbus

Type
Address Map

115

PLC Input (m is PLC input top word address for each axis number)

Address m

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Current Position

(Lower word)

Address m+1

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Current Position

(Upper word)

(Note) If the target position is a negative value, it is indicated by a two’s complement.

Address m+2

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Command

Current

(Lower word)

32,768

16,384

8,192

4,096

2,048

1,024

512

256

128

64

32

16

8

4

2

1

Address m+3

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Command

Current

(Upper word)

524,288

262,144

131,072

65,536

Address m+4

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Current Speed

(Note) If the current speed is a negative value, it is indicated by a two’s complement.

Address m+5

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Cannot be used.

Address m+6

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Alarm Code

Address m+7

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

Status Signal

E

M

G

S

CRDY

ZO

N

E

2

ZO

N

E

1

MEND

A

LM

L

P

S

FL

S

V

A

LM

M

O

V

E

HEND

P

E

N

D

1 word = 16 bit