Chapter 2 wiring – IAI America MSEP User Manual

Page 49

Advertising
background image

Chapter 2 Wiring

41

2) List of PIO Signals

The table below lists the functions of PIO signals. Refer to the section shown in Relevant

Sections for the details of the control of each signal.

Category

Signal

Abbreviation

Signal Name

Function Description

Relevant

Sections

ST0

• Moving Signal

(Single Solenoid

System)

• Backward End

Movement Signal

(Double Solenoid

System)

• Move Signal 1

(PIO Pattern 3)

ST1

• Forward End

Movement Signal

• Move Signal 2

(PIO Pattern 3)

ST2

• Intermediate Point

Movement Signal

The positioning to the corresponding target position is

performed, when the signal leading edge created in the

mode change from OFF to ON, or ON level is detected.

3.8.2

[4] [5]

*STP

Pause

When this signal is turned OFF while in move, the

actuator decelerates and then stops. The remaining

movement is in a hold while the actuator is stopped and

will resume when the signal turns back ON.

3.8.2 [3]

RES

Reset

An alarm will be reset when this signal is turned ON.

(Note) Depending on the alarm level, alarm reset might

not be available. Refer to the Trouble Shooting for

the details.

3.8.2 [3]

SON

Servo ON

The servo remains ON while this signal is ON, or OFF

while this signal is OFF.

3.8.2 [1]

SPDC

Movement Speed

Change

To change the speed during a movement operation, input

the movement signal while this signal is ON.

(Note) This signal is available only in the operation

pattern 1.

3.8.2 [10]

CN1

Target Position Change

Turn this signal ON when an operation is made with a

change to the operation condition.

When this signal is turned ON or OFF during the

operation, the position data is changed.

(Note) This signal is available only in the operation

pattern 2.

3.8.2 [11]

Input

ASTR

Continuous

Reciprocating Operation

A back and forth movement is performed repeatedly

between the forward end and the backward end while this

signal is ON. When this signal is turned OFF during the

movement operation, after the actuator is positioned to

the current target, it is stopped.

(Note) This signal is available only in the operation

pattern 5.

3.8.2 [13]

LS0

Backward End Position

Detection

LS1

Forward End Position

Detection

LS2

Intermediate Point

Detection

The same operation as of the limit switch of the air

cylinder is performed.

It is turned ON when the current position is within the

positioning width for each position detection output.

3.8.2 [5]

PE0

Backward End Point

Positioning Completion

PE1

Forward End Point

Positioning Completion

PE2

Intermediate Point

Positioning Completion

This signal is turned ON when the current position goes

within the positioning width, and the positioning to the

target position is complete.

It is turned OFF in the Servo-Motor OFF mode or the

Emergency Stop Mode.

3.8.2 [4]

HEND

Home Return

Completion

This signal will turn ON when home return has been

completed.

It will be kept ON unless the home position is lost.

3.8.2 [6]

SV

Servo ON

This signal will remain ON while the servo is ON.

3.8.2 [1]

Output

*ALM

Alarm Output

This signal remains ON in normal conditions of use and

turns OFF when an alarm is generated.

3.8.2 [2]



Signal with “*” expresses the signal of active low. In the controller, the process is held when the input signal is turned OFF.