IAI America MSEP User Manual

Page 195

Advertising
background image

3.10 Status LED

187

2) For Fieldbus Type DeviceNet

SYS

EMG MODE

T C ERR

MS NS

{

: Illuminating, ×: OFF, ڏ: Flashing

Symbol

Lamp

Condition

Color

Description

Green

Ready

Orange

Alarm generated

SYS

(System status)

×

Power is OFF or in initializing

Red

Emergency stop

EMG

(Emergency stop

status)

×

Normal

Green

AUTO Mode

MODE

(AUTO/MANU status)

×

MANU Mode

Orange

Controller internal communication error

T ERR

(Controller internal

communication status)

×

Normal

Orange

Fieldbus communication error

C ERR

(Fieldbus

communication status)

×

Normal

Green

Online (Normal)

ڏ



Green

Online (Even though the network is established

normally, the master does not identify as MSEP)

Orange

An error occurs.

ڏ



Orange

No response returned from another slave device

NS

ڏ



Green/Orange

(Blink by turn) In self-checking process.

Green

Communication in normal condition

ڏ



Green

Parameter setting error

Orange

It is caused by the hardware breakdown.

ڏ



Orange

Light malfunction

MS

ڏ



Green/Orange

(Blink by turn) In self-checking process.

Advertising