3.5 Control Signals for PIO Operation

143

3.5 Control Signals for PIO Operation

The contents of the signals for the input and output ports vary depending on the setting of the

operation mode.

Set the position data from a teaching tool such as the RC PC software.

The number of movement points available in the operation depends on the operation pattern

(PIO pattern) input in the initial setting.

The I/O specifications for the operation pattern are described as follows.

PIO Pattern

Operation Details

I/O Type

0

Point-to-Point

Movement

2 positioning points, pause available

1

Movement Speed

Setting

2 positioning points, pause available

Speed setting can be changed during a

movement between the two types already

registered

2

Target Position

Change

2 positioning points, pause available

Target position can be changed for an operation

3

2-Input, 3-Point

Movement

3 positioning points, no pause available

Specify the movement position with a combination

of two signals

4

3-Input, 3-Point

Movement

3 positioning points, no pause available

Specify the movement position with a combination

of three signals

5

Automatic Back and

Forth Operation

2 positioning points, pause available

Movement is made repeatedly between 2 points.

6

Cannot be used.



The ROBO Cylinder functions capable to control in this mode are as described in the table below.

Operation Pattern (PIO Pattern)

0

1

2

3

4

5

ROBO cylinder function Point-to-

Point

Movement

Movement

Speed

Setting

Target

Position

Change

2-Input,

3-Point

Movement

3-Input,

3-Point

Movement

Automatic

Back and

Forth

Operation

Home-return operation

{

(Note 1)

Positioning operation

{

Speed and

acceleration/decelerati

on setting

{

Pitch feed (inching)

u

Pressing operation

{

Speed change during

movement

u

{

u

u

u

u

Operation at different

acceleration and

deceleration

{

Pause

{

{

{

u

u

{

Zone signal output

u

Target Position Change

u

u

{

u

u

u

(Note1) Home-return operation is performed at the first movement (ST0) if MANU is selected in

the initial setting. Home-return operation is performed at the first servo-on after the

power is turned ON if AUTO is selected.