IAI America MSEP User Manual

Page 66

Advertising
background image

Chapter 2 Wiring

58

2.4.3

Connection of Drive Cutoff/Emergency Stop Input Connector

Insert wires if an emergency stop input is desired individually for each slot or drive cutoff for

each slot. Unless it is desired, the controller can be used in the condition that the enclosed

short-circuit line is connected.

Insert the wires to the enclosed connector (plug). Strip the sheath of the applicable wires for

10mm and insert them to the connector. Push a protrusion beside the cable inlet with a small

slotted screwdriver to open the inlet. Once the cable is inserted, take the slotted screwdriver

OFF the protrusion to fix the cable to the terminal.


Connector Name

Drive Cutoff/Emergency Stop Input Connector

Cable Side

FMCD1.5/8-ST-3.5

Enclosed in standard package

Manufactured by PHOENIX

CONTACT

Controller Side

MCDN1.5/8-G1-3.5P26THR

Pin No.

Signal Name

Description

Applicable cable

diameter

1

MPOSLOT1

For motor power output slot 1

(Axis No. 2 and 3)

2

MPISLOT1

For motor power input slot 1

(Axis No. 2 and 3)

3

MPOSLOT0

For motor power output slot 0

(Axis No. 0 and 1)

4

MPISLOT0

For motor power input slot 0

(Axis No. 0 and 1)

KIV1.25 to 0.5mm

2

(AWG16 to 20)

Select the cable

thickness allowable for

the current figured out in

the power capacity.

1

2

3

4

5

7

8

6

9

10

11

12

13

14

15

16

Front view of connector

on controller side

5

EMG+24VSLOT1 For emergency stop power

output slot 1 (Axis No. 2 and 3)

6

EMGINSLOT1

For emergency stop power

input slot 1 (Axis No. 2 and 3)

7

EMG+24VSLOT0 For emergency stop power

output slot 0 (Axis No. 0 and 1)

8

EMGINSLOT0

For emergency stop power

input slot 0 (Axis No. 0 and 1)

KIV0.5 to 0.2mm

(AWG20 to 24)

9

MPOSLOT3

For motor power output slot 3

(Axis No. 6 and 7)

10

MPISLOT3

For motor power input slot 3

(Axis No. 6 and 7)

11

MPOSLOT2

For motor power output slot 2

(Axis No. 4 and 5)

12

MPISLOT2

For motor power input slot 2

(Axis No. 4 and 5)

KIV1.25 to 0.5mm

2

(AWG16 to 20)

Select the cable

thickness allowable for

the current figured out in

the power capacity.

13

EMG+24VSLOT3 For emergency stop power

output slot 3 (Axis No. 6 and 7)

14

EMGINSLOT3

For emergency stop power

input slot 3 (Axis No. 6 and 7)

15

EMG+24VSLOT2 For emergency stop power

output slot 2 (Axis No. 4 and 5)

16

EMGINSLOT2

For emergency stop power

input slot 2 (Axis No. 4 and 5)

KIV0.5 to 0.2mm

(AWG20 to 24)

Advertising