3.4 Fieldbus

Type

Address Map

132

5) Writing of Acceleration

PLC Output (Address n is the input and output top address for MSEP.)

(Note) If the writing is finished in normal condition, the same content as the demand command

is returned to the response command. If an error is generated, an error response is

returned. [Refer to this Section 16).]

Bit

Address

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

n+2

Demand

Command

[1005h]

0

0

0

1

0

0

0

0

0

0

0

0

0

1

0

1

n+3

Data 0

[Position No.]

128

64

32

16

8

4

2

1

n+4

Data 1

[Acceleration]

256

128

64

32

16

8

4

2

1

n+5

Data 2

[0]

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

W

rit

in

g o

f A

cc

el

er

at

io

n

n+6

Data 3

[Axis No.]

4

2

1



6) Writing of Deceleration

PLC Output (Address n is the input and output top address for MSEP.)

(Note) If the writing is finished in normal condition, the same content as the demand command

is returned to the response command. If an error is generated, an error response is

returned. [Refer to this Section 16).]

Bit

Address

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

n+2

Demand

Command

[1006h]

0

0

0

1

0

0

0

0

0

0

0

0

0

1

1

0

n+3

Data 0

[Position No.]

128

64

32

16

8

4

2

1

n+4

Data 1

[Deceleration]

256

128

64

32

16

8

4

2

1

n+5

Data 2

[0]

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

W

rit

in

g o

f D

ec

el

er

at

io

n

n+6

Data 3

[Axis No.]

4

2

1



1 word = 16 bit

1 word = 16 bit